- 支持实单!UV TRON 火焰探测器
UV TRON 火焰探测器 R9454 R9533
R9454:
Spectral Response (Short)
185 nm
Spectral Response (Long)
260 nm
Window Material
UV glass
Weight
Approx. 1.5 g
Discharge Starting Voltage (with UV radiation) (Max.)
360 Vdc
Recommended Operating Voltage
400 +/-25 Vdc
Background (Max.) *a
10 min-1
Sensitivity (Typ.) *b
4000 min-1
Maximum Ratings Supply Voltage
500 Vdc
Maximum Ratings Peak Current *c
30 mA
Maximum Ratings Average Discharge Current *d
1 mA
Operating Temperature
-20 to+60 deg. C
Note :
(*a) This is the maximum momentary current that can be handled if its full width at half maximum is less than 10 us.
(*b) If the tube is operated near this or higher, the service life is noticeably reduced. Use the tube within the recommended current values.
(*c) Measured under room illuminations (approximately 500 lux) and recommended operating conditions. Note that these values may increase if the following environmental factors are present.
1. Mercury lamps, sterilization lamps, or halogen lamps are located nearby.
2. Direct or reflected sunlight is incident on the tube.
3. Electrical sparks such as welding sparks are present.
4. Radiation sources are present.
5. High electric field (including static field) generates across the tube.
(*d) These are representative values for a wavelength of 200 nm and a light input of 10 pW/cm2. In actual use, the sensitivity will vary with the wavelength of the
ultraviolet radiation and the drive circuitry employed.R9533:
Spectral Response (Short)
185 nm
Spectral Response (Long)
260 nm
Window Material
UV glass
Weight
Approx. 2.5 g
Discharge Starting Voltage (with UV radiation) (Max.)
280 Vdc
Recommended Operating Voltage
350 +/-25 Vdc
Background (Max.) *a
10 min-1
Sensitivity (Typ.) *b
10000 min-1
Maximum Ratings Supply Voltage
400 Vdc
Maximum Ratings Peak Current *c
30 mA
Maximum Ratings Average Discharge Current *d
1 mA
Operating Temperature
-25 to+125 deg. C
Note :
(*a) This is the maximum momentary current that can be handled if its full width at half maximum is less than 10 us.
(*b) If the tube is operated near this or higher, the service life is noticeably reduced. Use the tube within the recommended current values.
(*c) Measured under room illuminations (approximately 500 lux) and recommended operating conditions. Note that these values may increase if the following environmental factors are present.
1. Mercury lamps, sterilization lamps, or halogen lamps are located nearby.
2. Direct or reflected sunlight is incident on the tube.
3. Electrical sparks such as welding sparks are present.
4. Radiation sources are present.
5. High electric field (including static field) generates across the tube.
(*d) These are representative values for a wavelength of 200 nm and a light input of 10 pW/cm2. In actual use, the sensitivity will vary with the wavelength of the
ultraviolet radiation and the drive circuitry employed.
型号 | 厂商 | 批号 | 数量 | 封装 | 交易说明 | 询价 | |
---|---|---|---|---|---|---|---|
24PCEFA6D | HONEYWELL/霍尼韦尔 | 2024+ | 341 | SIP | 授权代理 正品现货支持实单! | ||
26PC01SMT | HONEYWELL/霍尼韦尔 | 2024+ | 1241 | SIP | 授权代理 正品现货支持实单! | ||
FSS1500NGT | HONEYWELL/霍尼韦尔 | 2024+ | 1533 | SIP | 授权代理 正品现货支持实单! | ||
HIH6130-021-001 HIH-6130-021-001 | HONEYWELL/霍尼韦尔 | 2024+ | 13241 | SIP | 授权代理 正品现货支持实单! | ||
SS41F | HONEYWELL/霍尼韦尔 | 2024+ | 93121 | TO92 | 授权代理 正品现货支持实单! | ||
HEL-705-U-1-12-00 HEL-716-U-0-12-00 | HONEYWELL/霍尼韦尔 | 24+ | 3211 | SENSOR | 授权代理 公司现货支持实单! | ||
163PC01D75 | HONEYWELL/霍尼韦尔 | 24+ | 202 | SIP | 最新到货 支持实单! | ||
AWM3100V | HONEYWELL/霍尼韦尔 | 25+ | 488 | SIP | 霍尼韦尔授权代理 气体流量传感器 AWM3100V | ||
FSS1500NST FSS1500NGT | HONEYWELL/霍尼韦尔 | 2024+ | 93121 | SMD | 授权代理 正品现货支持实单! | ||
HIH-4000-003 HIH4000-003 | HONEYWELL/霍尼韦尔 | 24+ | 53121 | Sensor | 霍尼韦尔 授权代理长期现货! | ||
CSNR161-006 | HONEYWELL/霍尼韦尔 | 2024+ | 1223 | SIP | 授权代理 正品现货支持实单! | ||
AWM3300V/AW3100V | HONEYWELL/霍尼韦尔 | 25+ | 323 | SIP | 授权代理 最新鲜货! |